         Detectable Gases

                          TDLGases

 

 
TDL100-P

The TDL100-P from TDL Sensors Ltd is a Tunable Diode Laser Gas Sensor in a single access port, probe configuration for stack monitoring and industrial process control.

The instrument can be configured for NH3 + moisture, HCl + moisture, HF + moisture, CO, and O2.


A Multi-laser option is available using the same instrument for multi-gas measurements such as NH3 + moisture + O2, HCl + moisture + O2, HF + moisture + O2, CO + O2, HCl + HF + moisture.


The 1m folded measurement path can be positioned to an optimum position within a stack by means of a slip flange.

The windows are protected by a reliable, high efficiency purging system.

 
Gas Detection limit* Max T (oC)
O2 0.02 % 1500
NH3 0.2 ppm 500
HCl 0.1 ppm 400
HF 0.05 ppm 400
H2O 0.15 ppm 1500
CO 1 ppm 1500
CO2 1 ppm 1500
CH4 1 ppm 300
H2S 15 ppm 300
NO
NO (mid-IR)
30 ppm
100 ppb (new)
300
SO2 (mid-IR) 1 ppm (new) 500
N2O 40 ppm 200
HCN 2.5 ppm 300
Call for other options. *Defined for 1m path, 296K, 1 bar. Limit depends on individual installation.** Lower detection limit option available.


 



 


 
 


Application areas

Stack Monitoring

Process Control

 

TDL Sensors Ltd